Manual econ sens + econ sens+ pro 3-phase Power Meter with Logging Function Version 1.40

Strona 2 - Content

Safety Instructions and Warranty Terms 7 Manual econ sens+ Version 1.40 The econ sens+ energy consumption meter can be used with various publ

Strona 3

Safety Instructions and Warranty Terms 8 Manual econ sens+ Version 1.40 If several econ sens+ devices are installed next to one another it is

Strona 4 - Warranty Terms

Safety Instructions and Warranty Terms 9 Manual econ sens+ Version 1.40 Installing the econ sens + in a 690V grid The econ sens + can also

Strona 5

Safety Instructions and Warranty Terms 10 Manual econ sens+ Version 1.40 Alignment of the coil with the current flow If possible, secure th

Strona 6 - Overview S0 model

Safety Instructions and Warranty Terms 11 Manual econ sens+ Version 1.40 Connecting the data outputs S0-Interface The consumption data measu

Strona 7 - Current path connections

Safety Instructions and Warranty Terms 12 Manual econ sens+ Version 1.40 RS485-Interface The econ sens + supported on this interface the fol

Strona 8 - S0 model

Safety Instructions and Warranty Terms 13 Manual econ sens+ Version 1.40 Connecting the network The econ sens+ energy consumption meter has a

Strona 9 - Connecting the voltage path

Safety Instructions and Warranty Terms 14 Manual econ sens+ Version 1.40 Figure 15: Internet protocol properties 1. Under “Start / Contro

Strona 10

Safety Instructions and Warranty Terms 15 Manual econ sens+ Version 1.40 Home menu On the home screen of the eco

Strona 11

Safety Instructions and Warranty Terms 16 Manual econ sens+ Version 1.40 Meter menu Econ sens+ displays the measured values in tabular form

Strona 12

Content Safety Instructions and Warranty Terms ... 1 Safety Instructions ...

Strona 13

Safety Instructions and Warranty Terms 17 Manual econ sens+ Version 1.40 You can also have the voltage and the current on the three phases di

Strona 14 - S0-Interface

Safety Instructions and Warranty Terms 18 Manual econ sens+ Version 1.40 Installation check routine „Installation check“ The econ sens + has

Strona 15 - Modbus RTU

Safety Instructions and Warranty Terms 19 Manual econ sens+ Version 1.40 Note: Due to the simplicity of the installation check routine, there

Strona 16 - Accessing the web interface

Safety Instructions and Warranty Terms 20 Manual econ sens+ Version 1.40 Graph menu In the Graph menu, the measurement results are represente

Strona 17

Safety Instructions and Warranty Terms 21 Manual econ sens+ Version 1.40 Events menu The Events menu is used to configure the recording of ne

Strona 18 - Home menu

Safety Instructions and Warranty Terms 22 Manual econ sens+ Version 1.40 General information on saving settings The overall configuration pr

Strona 19 - Meter menu

Safety Instructions and Warranty Terms 23 Manual econ sens+ Version 1.40 When you click on Accept, the econ sens+ first of all checks the co

Strona 20

Safety Instructions and Warranty Terms 24 Manual econ sens+ Version 1.40 In the info area, the MAC address of the device is shown at the top.

Strona 21 - Figure 21: Error message

Safety Instructions and Warranty Terms 25 Manual econ sens+ Version 1.40 Explanation of the settings: The European region generally has 230/

Strona 22

Safety Instructions and Warranty Terms 26 Manual econ sens+ Version 1.40 With an optional activation key the econ sens

Strona 23 - Graph menu

Content Settings menu ... 21 General

Strona 24 - Settings menu

Safety Instructions and Warranty Terms 27 Manual econ sens+ Version 1.40 Flicker severity The 3 supply phases are checked. The method used t

Strona 25 - Time/Date submenu

Safety Instructions and Warranty Terms 28 Manual econ sens+ Version 1.40 Frequency drift The supply frequency is checked. Sudden frequency ch

Strona 26 - Network submenu

Safety Instructions and Warranty Terms 29 Manual econ sens+ Version 1.40 Events (Proversion) submenu For each event up to 6 parameters are lo

Strona 27 - Electrical submenu

Safety Instructions and Warranty Terms 30 Manual econ sens+ Version 1.40 Pulses / s submenu Every pulse that is outputted via the two pulse

Strona 28

Safety Instructions and Warranty Terms 31 Manual econ sens+ Version 1.40 Modbus Pulses / s (S0/RS 485-Variante) submenu The settings for the

Strona 29

Safety Instructions and Warranty Terms 32 Manual econ sens+ Version 1.40 Modbus register address ranges Range Contents Data size & type

Strona 30

Safety Instructions and Warranty Terms 33 Manual econ sens+ Version 1.40 i(L3) 34 Current (Present value) L3 A p(L1) 36 Real Power (Present v

Strona 31

Safety Instructions and Warranty Terms 34 Manual econ sens+ Version 1.40 Name Register Description Phase Units i tot 120 Current, total (P

Strona 32 - Events (Proversion) submenu

Safety Instructions and Warranty Terms 35 Manual econ sens+ Version 1.40 Modbus Event Setting Registers The event settings are also availabl

Strona 33 - Pulses / s submenu

Safety Instructions and Warranty Terms 36 Manual econ sens+ Version 1.40 Modbus Event Value Registers Pst is the short term flicker value fo

Strona 34 - Description

Safety Instructions and Warranty Terms 1 Manual econ sens+ Version 1.40 Safety Instructions and Warranty Terms Safety Instructions Intended

Strona 35

Safety Instructions and Warranty Terms 37 Manual econ sens+ Version 1.40 Pass submenu In the Pass submenu you can change your password and u

Strona 36

Safety Instructions and Warranty Terms 38 Manual econ sens+ Version 1.40 Save submenu The Save submenu is used to save or restore settings

Strona 37 - Table Modbus – Events

Safety Instructions and Warranty Terms 39 Manual econ sens+ Version 1.40 Deletion of all event recordings: Deletes all data from the d

Strona 38 - Event halflife time

Safety Instructions and Warranty Terms 40 Manual econ sens+ Version 1.40 Initial Operation For initial operation of the econ sens+ proceed

Strona 39

Safety Instructions and Warranty Terms 41 Manual econ sens+ Version 1.40 Troubleshooting 1.) The S0 outputs of the Econ Sens + supply no p

Strona 40 - Pass submenu

Safety Instructions and Warranty Terms 42 Manual econ sens+ Version 1.40 e.) The coils for current measurement are wrongly aligned (label do

Strona 41 - System submenu

Safety Instructions and Warranty Terms 43 Manual econ sens+ Version 1.40 maintenance work, etc.), it may be that the sens+ has received a new

Strona 42 - Manual menu

Safety Instructions and Warranty Terms 44 Manual econ sens+ Version 1.40 Technical data econ sens+ basic unit

Strona 43 - Initial Operation

Safety Instructions and Warranty Terms 45 Manual econ sens+ Version 1.40 Dimensions / mm

Strona 44 - Troubleshooting

Safety Instructions and Warranty Terms 46 Manual econ sens+ Version 1.40 econ sens+ measuring coils: Default settings

Strona 45

Safety Instructions and Warranty Terms 2 Manual econ sens+ Version 1.40 All information contained in this manual was prepared to the best of

Strona 46

Safety Instructions and Warranty Terms 3 Manual econ sens+ Version 1.40 minutes) for the last 13 months and per day for the last 10 years. No

Strona 47 - Technical data

Safety Instructions and Warranty Terms 4 Manual econ sens+ Version 1.40 S0-pulse outputs Imp - : Pulse output (Open Collector, NPN) f

Strona 48 - Dimensions /

Safety Instructions and Warranty Terms 5 Manual econ sens+ Version 1.40 Ethernet connection Ethernet: Ethernet connection (RJ45) / 100 Mb

Strona 49 - Default settings

Safety Instructions and Warranty Terms 6 Manual econ sens+ Version 1.40 Further details on the connections can be found in the “Te